DTS100 Z-Axis CNC Tool Setter for Tool Length Measurement

DTS100 Z-axis contact tool setter supports automatic tool length measurement and tool breakage checks using compatible CNC cycles. It features <1 μm (2σ) repeatability at 50 mm/min, a Ø10 mm tungsten carbide pad, normally closed output, IP68 protection and a 5 m cable.

Partagez votre amour

DTS100 is a compact Z-axis contact tool setter designed for automatic tool length measurement and tool offset setting on CNC machining centers. A cutting tool approaches the tungsten carbide touch pad along the +Z triggering direction, and the unit sends a contact signal to a compatible CNC input through its wired connection.

The DTS100 provides specified repeatability below 1 μm (2σ) at a probing speed of 50 mm/min. Its Ø10 mm contact pad, normally closed (NC) electrical output and 5 m oil-resistant six-core cable support integration into suitable machine setups. IP68 sealing and a protective cable conduit are intended for industrial machining environments.

With appropriate CNC measurement macros, the tool setter can also support tool length verification and basic tool breakage checks. Qidu provides technical assistance for machine compatibility, mounting location, wiring, calibration and measurement cycle configuration. Confirm available clearances, controller signal requirements and the required installation accessories before ordering.

Model

DTS100

Product Type

Z-Axis Contact CNC Tool Setter

Contact Pad Diameter

Ø10 mm

Trigger Direction

+Z

Repeatability

<1 μm (2σ)

Repeatability Test Speed

50 mm/min

Pre-Stroke

0.5 mm

Z-Axis Stroke

6.0 mm

Trigger Protection Distance

3.5 mm

Trigger Force

1.8 N (vertical installation)

Output Configuration

Normally Closed (NC)

Signal Transmission

Hard-Wired Cable

Contact Rating

DC 24 V, ≤20 mA, resistive load

Mechanical Trigger Life

>10 million cycles

Touch Pad Material

Tungsten Carbide

Cable Length

5 m

Cable Type

Oil-Resistant, 6-Core

Cable Outer Diameter

Ø4.8 mm

Protective Conduit Length

2 m

LED Status

Normal: ON; Activated: OFF

Protection Rating

IP68