DTS200S Compact Z-Axis CNC Tool Setter with Bellows Cover

DTS200S compact Z-axis contact tool setter features a bellows-style protective cover, Ø20 mm tungsten carbide pad, below 1 μm (2σ) repeatability at 50 mm/min, 8.5 mm axial stroke, normally open output, IP68 protection and a 5 m wired connection.

Condividi il tuo amore

DTS200S is a compact, wired Z-axis contact tool setter for automated tool length measurement, offset setting and programmed tool checks on CNC machining centers. Its Ø20 mm tungsten carbide contact pad registers contact in the +Z direction and sends a trigger signal through a normally open (NO) electrical output.

A distinguishing feature is the bellows-style cover surrounding the moving contact assembly. The cylindrical housing and round mounting base offer an alternative installation arrangement to rectangular tool setters, provided the machine has suitable clearance and mounting provisions.

The DTS200S has specified repeatability below 1 μm (2σ) at a probing speed of 50 mm/min. Its published movement characteristics include a 0.7 mm pre-stroke, 8.5 mm axial stroke and 5.5 mm trigger protection distance. It also features IP68 sealing and a 5 m oil-resistant, six-core cable.

With suitable CNC inputs and measurement macros, the DTS200S supports tool length setting, offset verification and basic tool breakage checks. Qidu provides guidance on installation, calibration, wiring and controller integration.

Model

DTS200S

Product Type

Z-Axis Contact CNC Tool Setter

Contact Pad Diameter

Ø20 mm

Trigger Direction

+Z

Repeatability

<1 μm (2σ)

Repeatability Test Speed

50 mm/min

Pre-Stroke

0.7 mm

Z-Axis Stroke

8.5 mm

Trigger Protection Distance

5.5 mm

Trigger Force

2.2 N (vertical installation)

Output Configuration

A: Normally Open (NO)

Signal Transmission

Hard-Wired Cable

Mechanical Trigger Life

>10 million cycles

Contact Pad Material

Tungsten Carbide

Cable Length

5 m

Cable Type

Oil-Resistant, 6-Core

Cable Outer Diameter

Ø4.8 mm

Electrical Contact Rating

DC 24 V, ≤20 mA, resistive load

Protective Conduit Length

2 m

Minimum Protective Conduit Bend Radius

7 mm (as specified)

LED Status

Normal: OFF; Activated: ON

Protection Rating

IP68