DTS100S Z-Axis Contact CNC Tool Setter for Tool Length

DTS100S Z-axis contact tool setter supports automatic tool length measurement and tool breakage checks through compatible CNC cycles. It features <1 μm (2σ) repeatability at 50 mm/min, a Ø10 mm tungsten carbide contact pad, NC output, IP68 protection and a 5 m oil-resistant cable.

Comparte tu aprecio

DTS100S is a compact Z-axis contact tool setter for automated tool length measurement, offset setting and tool checks on CNC machining centers. Mounted at a fixed position, its tungsten carbide contact pad detects a cutting tool approaching in the +Z triggering direction and sends a signal to a compatible CNC control input.

The DTS100S has specified repeatability below 1 μm (2σ) at a probing speed of 50 mm/min. It uses a normally closed (NC) output and a 5 m oil-resistant, six-core cable. Its Ø10 mm contact pad, IP68 sealing and flexible protective conduit suit appropriately configured machining environments. The illustrated model also features a bellows-style cover around the sensing element.

With suitable measurement macros, the DTS100S can support programmed tool length setting, offset verification and basic tool breakage checks. Qidu provides assistance with product selection, wiring, mounting, calibration and controller integration. Confirm available machine clearance and connection requirements before ordering.

Model

DTS100S

Product Type

Z-Axis Contact CNC Tool Setter

Contact Pad Diameter

Ø10 mm

Trigger Direction

+Z

Repeatability

<1 μm (2σ)

Repeatability Test Speed

50 mm/min

Pre-Stroke

0.5 mm

Z-Axis Stroke

6.0 mm

Trigger Protection Distance

3.5 mm

Trigger Force

1.8 N (vertical installation)

Output Configuration

A: Normally Closed (NC)

Signal Transmission

Hard-Wired Cable

Mechanical Trigger Life

>10 million cycles

Cable Length

5 m

Cable Type

Oil-Resistant, 6-Core

Cable Outer Diameter

Ø4.8 mm

Touch Pad Material

Tungsten Carbide

Electrical Contact Rating

DC 24 V, ≤20 mA, resistive load

Protective Conduit Length

2 m

LED Status

Normal: ON; Activated: OFF

Protection Rating

IP68